These 10 mil and 15 mil vapor barriers are very puncture resistant and will not break down over time creating a true moisture barrier between the sub grade and.
Vapor barrier below concrete slab.
If you are going to seal an exterior slab find a sealer that transmits water vapor breathes.
Should you put a vapor barrier under concrete slabs.
Their use should be avoided where ground moisture conditions permit.
One laboratory drying study indicated that 4 in.
A below slab vapor barrier can also help prevent sub slab radon ingress.
When evaluating the performance qualities of vapor barriers as soil gas retarders be sure to check the radon diffusion coefficient of the material before you select it.
Chemical resistance consideration if a vapor barrier is being used under a slab to control vapors at a brownfields site the chemical resistance of the vapor barrier must be considered.
Their 15 mil vapor barrier also controls radon gas is resistant to hot cold temperatures resistant to soil chemicals pollutants and like i said allows virtually zero water vapor transmission up through the slab.
Aci 302 1 which is an american concrete institute standard for slab construction was modified in the early 2000 s to reflect the change in the placement of the vapor barrier directly below the concrete if a low permeable membrane flooring was to be installed.
The rate that moisture escapes from a slab depends on the concrete w c the density of the finish the ambient conditions above the slab and the moisture below the slab.
Florprufe vapor barriers gcp lied slab vapor barrier by professional concrete floor problems building under monolithic concrete slab 10 and 15 mil underslab vapor barrier concrete vapor barriers ers.
Stego wrap claims they have a virtually zero permeance under concrete slab vapor barrier.
Thick concrete samples having a w c 0 50 and sealed from below required 82 days for the vapor emission rate to reach 3 0.
If heavy equipment will be operating on the vapor barrier or if the vapor barrier will be installed over an angular subbase a minimum of 15 mils is recommended.
A much better approach is a true vapor barrier with characteristics that conform to the requirements of astm e 1745 standard specification for water vapor retarders used in contact with soil or granular fill under concrete slabs.
Most exterior slabs do not need a vapor barrier.
Many vapor barriers are synonymous with soil gas retarders in construction language.
Thin plastic like this is often called a vapor retarder meaning it slows the vapor down but doesn t stop it.
Vapor barriers aggravate the problems of plastic and shrinkage cracking.
For some tips on this see sullivan s corner.
Stego wrap 15 mil vapor barrier.